Covering all of Greater London inside the M25 Mon–Fri 08:00–18:00, Sat 09:00–14:00
Electrical safety

Domestic EICR London

A full electrical inspection of your London house or flat, whether you are buying, selling, renovating or letting a single home. Carried out by NICEIC / NAPIT registered electricians.

Prices include VAT All London inside the M25 Digital certificate
Quick answer

A domestic EICR is an inspection and test of the fixed wiring in a house or flat, assessed against BS 7671. Owner-occupiers are commonly advised to have one every 10 years and when buying, selling or renovating, while landlords are legally required to arrange one at least every 5 years. BritCertify inspects London homes from £79 inc. VAT and usually emails the report within 24–48 hours.

Does a homeowner need an EICR?

No law requires owner-occupiers in England to have an EICR, but an inspection at least every 10 years is commonly recommended for a home you live in. Rented homes are different: a private landlord is legally required to arrange an inspection and test at least every 5 years.

A domestic EICR is the same formal report a landlord receives, carried out to BS 7671 (the IET Wiring Regulations). It records the condition of the consumer unit, earthing and bonding, circuits, sockets, switches and light fittings, and flags anything that is dangerous or deteriorating. Electrical inspections are carried out by NICEIC / NAPIT registered electricians, qualified to BS 7671.

When is a home electrical inspection worth booking?

The most useful moments are when a home changes hands, before building work, and whenever the wiring is old or behaving oddly. These are the common reasons homeowners and single-property landlords book one.

  • Buying a house or flat. A buyer’s survey often recommends that the electrics are tested by a qualified electrician. An EICR before you exchange shows whether you are taking on a few minor repairs or something larger, which is useful when agreeing a price.
  • Selling. A recent report answers buyers’ questions about the electrics with evidence, and gives you the chance to fix obvious defects before viewings.
  • Before a renovation. A new kitchen, bathroom, extension or loft conversion adds load and new circuits. Knowing the condition of what is already there helps your electrician price the job accurately and avoids surprises once walls are open.
  • Older wiring. If the fuse box still has rewireable fuses, the cables are an old colour scheme, or nobody knows when the house was last rewired, an inspection gives you a reliable baseline.
  • Insurer or lender requests. Some insurers and mortgage lenders ask for evidence of the electrical condition, particularly for older properties.
  • Letting a single flat or house. Once you rent a home out, the 5-year inspection becomes a legal duty rather than a choice.

What happens during a domestic EICR visit in a London home?

The electrician starts at the incoming supply, works out how the home is fed and protected, then inspects and tests every circuit on the consumer unit. Most of the time is spent at the fuse board, with short trips to each room to check accessories and take readings.

London housing brings its own practicalities. In Victorian terraces split into flats, the meters often sit together under the communal stairs or in a basement, with a cable running from each meter up to the flat’s own consumer unit. That cable is usually part of the flat’s installation, so we need access at both ends. Purpose-built blocks commonly keep meters in a locked room controlled by the managing agent, and in some older conversions we find a supply shared between flats or with the communal lighting. Where that happens, the report says so plainly, because it affects who is responsible for which part.

Our electricians also regularly come across older rewireable fuse boards in homes that have not been rewired for decades: wooden or metal-cased units with fuse wire in ceramic carriers and little or no RCD protection. An old board is not automatically dangerous. It is tested and assessed like any other, and the report explains whether an upgrade such as a consumer unit replacement is advisable.

What signs of older wiring do our electricians look out for?

Many clues are visible before any testing starts. Here is what you might notice at home and what it usually tells an electrician.

What you might noticeWhat it can point toWhat the electrician does
Fuse box with pull-out fuse carriers and fuse wireAn older rewireable board, often without RCD protectionTests each circuit and records whether additional protection is needed
Red and black cables at the board or behind a switchWiring installed under the older colour schemeChecks insulation resistance and looks for a warning notice where old and new colours meet
Black rubber-covered cable in the loft or under floorsVery old insulation that can become brittle and crumbleInspects what is accessible; perished insulation is flagged for attention
Breakers tripping, flickering lights or warm socketsLoose connections, overloaded circuits or failing accessoriesInvestigates the circuit; any scorching or overheating is treated as a priority
Extension leads and adaptors in most roomsToo few sockets for modern useChecks the circuits involved and may recommend extra sockets

None of these signs decides the result on its own. The test readings and the actual condition of each circuit determine how an observation is coded.

How long does a home EICR take, and will the power be off?

A studio or one-bedroom flat usually takes a few hours, while a larger house with more circuits can take most of a day. The power goes off in stages during testing, so expect several short interruptions rather than one long outage.

Time on site depends on the number of circuits, how easy the consumer unit and meter position are to reach, and whether circuits are labelled. An unlabelled board, a second consumer unit for an extension, or circuits that cross between flats all take longer to trace. Plan around fridges, freezers, alarm systems and home working on the day. The finished report is usually emailed within 24–48 hours.

What do the codes on a domestic EICR mean?

Each observation is given a code that reflects how serious it is. Any C1, C2 or FI gives an unsatisfactory overall result, whereas a report showing only C3s is still satisfactory.

  • C1: danger present, immediate action required.
  • C2: potentially dangerous, urgent remedial action required.
  • C3: improvement recommended.
  • FI: further investigation required without delay.

Owner-occupiers have no legal deadline to act, but C1 and C2 items describe real risks and are worth putting right promptly. Our article on EICR codes C1, C2, C3 and FI walks through typical findings for each code.

What does a domestic EICR not cover?

An EICR covers the fixed electrical installation only. It is not a pass or fail certificate for the things you plug in, and it is not the paperwork issued for new electrical work.

  • Plug-in appliances such as kettles, lamps, heaters and televisions are outside its scope. If you supply appliances with a let, PAT testing is the separate check for those.
  • New wiring is certified with an Electrical Installation Certificate or a Minor Electrical Installation Works Certificate, issued by whoever carries out the work.
  • Gas appliances are not inspected. The electrician checks the protective bonding to the gas pipe, not the boiler or hob.
  • Concealed cables are not exposed. Walls are not opened, and any parts that could not be reached are listed on the report as limitations.

The report is also a snapshot. It records the condition on the day and recommends a date for the next inspection, which may be sooner than 10 years for an older installation.

What do landlords of a single flat or house need to know?

If you let your home, the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require an inspection and test at least every 5 years, a copy of the report for your tenants, and remedial work within 28 days where the report calls for it. Breaches can lead to council penalties of up to £30,000 each.

The inspection itself is identical; the paperwork duties are what change. Our full landlord EICR guide covers the deadlines, who must receive a copy and the Private Rented Sector Database. If you are letting a former home for the first time, book the inspection before the tenancy starts so the new tenant can have the report before moving in. To price your home, send us the number of bedrooms and consumer units through our quote form.

Domestic EICR prices in London (inc. VAT)

Domestic EICR prices in London (inc. VAT)
OptionPrice (inc. VAT)Notes
Studio flat£79Price covers one consumer unit
1–2 bedroom flat or house£99Price covers one consumer unit
3–4 bedroom flat or house£119Price covers one consumer unit
5–6 bedroom house£149Price covers one consumer unit
Each additional consumer unit£65–£85For example a second board serving an extension or garden room

Prices include VAT and cover one consumer unit; each additional consumer unit is £65–£85. Central London parking or Congestion Charge may be added; we always confirm before booking.

Book this service

What's included

  • Inspection and testing of your home's fixed wiring to BS 7671
  • All circuits and RCDs on one consumer unit tested
  • Checks on earthing and bonding to gas and water pipes
  • Digital report emailed, usually within 24–48 hours
  • Coded observations explained in plain English
  • Recommended date for your next inspection
  • Fixed-price quote for any repairs or upgrades

How it works

  1. Tell us about your home

    Share the number of bedrooms, consumer units and where the meter sits. We confirm the price inc. VAT and any parking charge before booking.

  2. Electrician visits

    A NICEIC / NAPIT registered electrician inspects the installation and tests each circuit, switching the power off in short stages.

  3. Report emailed

    Your EICR arrives, usually within 24–48 hours, with an overall result, coded observations and a recommended date for the next inspection.

  4. Repairs if needed

    If anything needs attention, we give you a fixed price for the work and certify it once it is complete.

Domestic EICR: frequently asked questions

Can I arrange an EICR on a house I am buying in London?

Yes, with the seller's permission. Your estate agent can usually arrange access, and the seller needs to agree to the power being switched off in stages during testing. The report gives you a clear picture of the electrics before you commit, and any C1 or C2 observations can be priced so you know what work to budget for after completion.

How often should homeowners have their electrics inspected?

An inspection at least every 10 years is commonly recommended for an owner-occupied home, and the electrician may suggest a shorter interval for an older installation. It is also sensible to book one when you buy a property, before major renovation work, or if you notice warning signs such as tripping breakers, scorch marks or warm sockets.

Do homeowners have to fix the issues listed on an EICR?

There is no legal deadline for owner-occupiers. The 28-day remedial rule applies to private landlords under the 2020 regulations. Even so, C1 means danger is present and C2 means potentially dangerous, so both should be dealt with promptly. C3 items are recommendations you can plan around, for example as part of a future kitchen or bathroom project.

Does a domestic EICR test my appliances?

No. A domestic EICR covers the fixed installation: the consumer unit, wiring, sockets, switches, light fittings and hard-wired items such as an electric shower or immersion heater. Plug-in appliances are checked separately by PAT testing. Homeowners rarely need it, but landlords who supply appliances with a let must make sure they are safe, and PAT testing is a common way to show that.

Will an EICR tell me whether my home needs rewiring?

It gives you the evidence to decide. An EICR is a condition report rather than a rewiring survey, but it records the insulation test results, the condition of every circuit and any coded defects. Where cables have perished or several circuits show the same problems, the electrician explains in the observations that wider work is likely, and we can quote for it.

Can you inspect a flat whose meter is in a shared cupboard?

Yes. Shared meter cupboards are common in London conversions and blocks. We need access to the meter position and the flat's consumer unit, so please arrange keys or door codes from the managing agent or freeholder before the visit. If the flat's supply or earthing is shared with other flats or the communal areas, we record it on the report so responsibilities are clear.

Written and checked by the BritCertify technical team. Last reviewed 6 October 2026.

Book your Domestic EICR today

Tell us the property type and postcode and we will confirm a fixed price, including VAT, and the earliest available slot.