Smoke & CO Alarm Installation London

Smoke, heat and carbon monoxide alarms supplied and fitted in London rented and owner-occupied homes, positioned to meet the 2022 regulations and tested before we leave.

Prices include VAT All London inside the M25 Digital certificate
Quick answer

Smoke and CO alarm installation means supplying and fitting the alarms a home needs: at least one smoke alarm on every storey with living accommodation, and a carbon monoxide alarm in any room with a fixed combustion appliance, excluding gas cookers. Landlords who fall short face penalties of up to £5,000. BritCertify fits alarms across London for £129 per detector inc. VAT.

Which alarms does a rented home need under the 2022 regulations?

At least one smoke alarm on every storey with a room used wholly or partly as living accommodation, and a carbon monoxide alarm in any such room that contains a fixed combustion appliance, other than a gas cooker. The Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 have applied to private and social landlords in England since 1 October 2022.

Landlords must also check that alarms are working on the first day of each new tenancy and repair or replace an alarm once they are told it is faulty. The penalty for a breach can be up to £5,000. The government publishes an explanatory booklet for landlords with the full wording.

Turned into a fitting plan, room by room, that usually looks like this:

SpaceLegal minimum for landlordsWhat we usually recommend
Hallway or landing on each storeyA smoke alarm on every storey with living accommodationA ceiling-mounted smoke alarm on the escape route, linked to the others
Loft room or basement bedroomIf it is used as living accommodation, that storey needs a smoke alarmA smoke alarm linked to the rest, so a fire on another floor is heard there
Room with a gas boilerA CO alarmA CO alarm sited to the manufacturer’s instructions for that appliance
Room with a gas fire, wood burner or open fireA CO alarmThe same; solid fuel and gas appliances are both fixed combustion appliances
Kitchen with a gas cooker onlyNo CO alarm required for the cookerA heat alarm linked to the smoke alarms; some landlords add a CO alarm as well
Living roomNothing beyond the storey’s smoke alarmA smoke alarm, which moves the layout from escape-route cover towards fuller cover

Owner-occupiers are not covered by the 2022 regulations, but a fire or a faulty boiler is just as dangerous in your own home. We fit owner-occupied homes to the same principles, so the alarms are already in place if you later let the property.

Should you choose battery or mains-wired alarms?

The 2022 regulations do not specify the power source, so both can meet the legal minimum. The right choice depends on how the property is let, whether a licence or fire risk assessment asks for more, and how much disruption the building can take.

OptionHow it worksWhere it tends to suit
Sealed long-life battery alarmSelf-contained, with a battery the occupier cannot removeSingle-let flats where wiring is impractical, or a storey that has no alarm at all
Replaceable-battery alarmSelf-contained, with a battery the occupier changesRarely our recommendation for lets, because removed batteries are a common finding
Mains-wired with standby batteryPowered from the electrical installation, with a battery that keeps it working in a power cut. Grade D1 has a sealed standby battery, Grade D2 a replaceable oneMost rented houses and flats, and the usual starting point for shared houses
Interlinked alarmsMains or battery alarms connected by cable or radio, so one alarm sets off all of themAny home with more than one storey, or a long flat where an alarm at one end cannot be heard at the other

Whatever the power source, every alarm carries a manufacture or replace-by date. Alarms past that date should be replaced, and an interlinked set is usually best replaced together so that the models stay compatible with each other.

How do we decide where each alarm goes?

We start from the escape route and the appliances, then adjust for the layout and the manufacturer’s siting instructions, which come with every alarm and take priority over rules of thumb.

  • Smoke alarms go on the ceiling, where smoke gathers first, in the hallway and on each landing people would use to get out.
  • Smoke alarms stay clear of steam and cooking fumes. A smoke alarm just outside a bathroom or kitchen door is the alarm that ends up disabled. A heat alarm is the right device in the kitchen itself.
  • Alarms must be audible from the bedrooms with the doors shut, which in a long London flat or a three-storey house usually means interlinking.
  • CO alarms go in the room with the appliance: the boiler, gas fire, wood burner or open fire. Height and distance from the appliance follow the manufacturer’s instructions.
  • CO alarms are never hidden inside cupboards or behind furniture and curtains, where air cannot reach them freely.

In BS 5839-6 terms, smoke alarms on the escape route only are Category LD3. Adding detection in rooms where fire is more likely to start, such as the kitchen and living room, gives Category LD2.

When an HMO licence, a fire risk assessment or building work asks for it. The 2022 regulations are a floor, and several common London situations call for a higher specification.

  • HMOs: licence conditions often require mains-powered, interlinked alarms to a stated Grade and Category, such as Grade D1 or D2 with LD2 or LD3 coverage. Check your borough’s conditions before ordering alarms.
  • Fire risk assessment actions: where a building has shared parts or is used for short-lets, the assessment may specify upgraded alarms.
  • Loft conversions and extensions: a new storey with living accommodation needs its own smoke alarm, linked to the rest of the home.
  • Larger and bedsit-style HMOs: these often need a control panel system instead of standalone alarms. Our fire alarm installation service designs and fits full systems.

What happens on the installation visit?

The engineer confirms the plan, fits and links the alarms, tests everything and shows the occupants how it works.

  1. Walk-round: confirm the storeys, the escape route and every fixed combustion appliance, and note the age of any existing alarms.
  2. Fitting: fix each alarm in its agreed position. Mains-wired alarms are installed to BS 7671, and any new hole through a fire-resisting ceiling is sealed.
  3. Linking: set up the wired or radio interlink so that one alarm triggers the rest.
  4. Testing: test every alarm and, on linked systems, trigger each one in turn to prove it sets off the others.
  5. Handover: show occupants the test button, how to silence a nuisance alarm and how to report a fault.

In occupied rented homes, give tenants notice of the visit so every room with an alarm position can be reached.

What records do you get after fitting?

A written record of each alarm we fit: its location, type (smoke, heat or CO), power source and the date it was installed and tested. Keep it in the tenancy file, because it is the starting point for the first-day check on every future tenancy.

An installation record is not the same as a periodic landlord check. For the check at the start of each tenancy, or when an agent asks for a current certificate, our fire safety (smoke alarm) certificate tests every alarm and records the result, from £69 inc. VAT for up to 3 detectors.

A CO alarm warns occupants; it does not make an appliance safe. Gas appliances, fittings and flues in a rented home still need checking every 12 months by a Gas Safe registered engineer under regulation 36 of the Gas Safety (Installation and Use) Regulations 1998, which our gas safety certificate covers. If a CO alarm sounds, do not ignore it: get people into fresh air and have the appliance checked before it is used again.

How is smoke and CO alarm installation priced?

Smoke, heat and carbon monoxide alarms are supplied and fitted for £129 per detector inc. VAT, so a visit fitting three alarms costs £387. We confirm the alarm positions and the total, including any central London parking charge, before any work starts. Request a quote with the number of storeys and the rooms that have a boiler, gas fire or wood burner.

Electrical inspections are carried out by NICEIC / NAPIT registered electricians, qualified to BS 7671. We hold £5 million public liability insurance, and our engineers have been certifying London properties since 2018.

Smoke and CO alarm installation prices in London (inc. VAT)

Smoke and CO alarm installation prices in London (inc. VAT)
OptionPrice (inc. VAT)Notes
Smoke or heat alarm supplied & fitted£129Per detector
Carbon monoxide alarm supplied & fitted£129Per detector, sited to the manufacturer's instructions
3 alarms fitted in one visit£387For example a smoke alarm on two storeys and a CO alarm beside the boiler
Landlord smoke alarm certificate (up to 3 detectors)£69Check of existing alarms with a dated certificate

All prices include VAT and are charged per detector. Central London parking or Congestion Charge may be added; we always confirm before booking.

Book this service

What's included

  • Advice on alarm type, power source and positions for your layout
  • Supply of smoke, heat and carbon monoxide alarms
  • Ceiling-mounted smoke alarms on the escape route of every storey
  • CO alarms in rooms with a boiler, gas fire, wood burner or open fire
  • Mains wiring to BS 7671 and interlinking where specified
  • Test of every alarm and interlink before we leave
  • Written record of each alarm's location, type and power source

How it works

  1. Tell us the layout

    Share the number of storeys, where the boiler and any fires or wood burners are, and any HMO licence conditions. We recommend alarm types and positions.

  2. Agree the specification

    You receive a written quote listing each alarm, its position and power source, at £129 per detector inc. VAT.

  3. Fit and interlink

    Our engineer fits each alarm, installs mains wiring to BS 7671, sets up the interlink where specified and seals any new holes in fire-resisting ceilings.

  4. Test and record

    Every alarm and interlink is tested, occupants are shown the test button, and you receive a written record of what was fitted and where.

Smoke & CO Alarm Installation: frequently asked questions

Do homeowners have to fit smoke and CO alarms?

The Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 apply to private and social landlords, not to owner-occupiers. The risk in your own home is the same, though, so we fit owner-occupied homes to the same principles: a smoke alarm on every storey, ideally interlinked, and a CO alarm in any room with a boiler, gas fire, wood burner or open fire. If you later let the home, the regulations apply from the first tenancy.

Can you replace one faulty alarm in an interlinked set?

Usually, if a compatible replacement is still available. Interlinked alarms, whether wired or radio, generally need to come from the same manufacturer's range so they can communicate. If the set is old or the model has been discontinued, replacing the whole set together is often more sensible than mixing models. Remember that landlords must repair or replace an alarm once they are told it is faulty.

Does a carbon monoxide alarm have to be mains-wired?

No. The 2022 regulations require a CO alarm in any room used as living accommodation with a fixed combustion appliance, excluding gas cookers, but they do not specify the power source. Sealed battery CO alarms meet that requirement. Some mains-wired ranges include CO alarms that link to the smoke alarms, so a CO alarm in one room sounds throughout the home. We explain both options when we quote.

Will fitting mains-wired alarms damage my ceilings?

Usually very little. Each mains-wired alarm needs a power supply, and a wired interlink needs a cable between alarms. In occupied flats and period homes with decorative ceilings, radio-interlinked mains alarms keep cabling to a minimum. Where a cable has to run through a ceiling or floor, we explain the route and any making good before work starts, and seal any hole through a fire-resisting ceiling.

Do I need a smoke alarm in every bedroom?

Not under the 2022 regulations, which require at least one smoke alarm on each storey with living accommodation. BS 5839-6 describes higher levels of cover: Category LD3 protects the escape route, and LD2 adds rooms where fire is more likely to start, such as the kitchen and living room. HMO licences and fire risk assessments sometimes ask for more, so check what applies to your property first.

Will you give me a certificate after fitting the alarms?

Yes, in the form of a written installation record listing each alarm's location, type, power source and test result. The landlord check at the start of each tenancy is a separate job. For that, our fire safety (smoke alarm) certificate tests every alarm and records the result, from £69 inc. VAT for up to 3 detectors, and can be booked for the day the new tenancy begins.

Written and checked by the BritCertify technical team. Last reviewed 7 October 2026.

Book your Smoke & CO Alarm Installation today

Tell us the property type and postcode and we will confirm a fixed price, including VAT, and the earliest available slot.