Electrical safety

EICR Certificate London

Electrical Installation Condition Reports for London landlords, agents and homeowners, tested to BS 7671 by NICEIC / NAPIT registered electricians, with reports usually within 24–48 hours.

Prices include VAT All London inside the M25 Digital certificate
Quick answer

An EICR (Electrical Installation Condition Report) is a formal inspection and test of a property's fixed wiring, consumer unit, sockets and lighting against BS 7671. Landlords in England must have one at least every 5 years under the 2020 private rented sector regulations. BritCertify carries out EICRs across London from £79 inc. VAT, with the report usually emailed within 24–48 hours.

What does an EICR check in a London property?

An Electrical Installation Condition Report assesses the fixed wiring and everything connected to it: the consumer unit, earthing, cables, sockets, switches, light fittings and hard-wired appliances. It does not cover plug-in items such as kettles and lamps, which are dealt with separately by PAT testing.

The visit combines a visual inspection with instrument testing. With circuits isolated, our electrician confirms the continuity of protective conductors and measures insulation resistance to find damaged or deteriorating cables. With the power restored, live tests measure earth fault loop impedance, confirm polarity and check that each RCD trips within the required time. Electrical inspections are carried out by NICEIC / NAPIT registered electricians, qualified to BS 7671.

Part of the installationWhat our electrician checks
Consumer unit (fuse box)Condition of the enclosure, device ratings, RCD protection, labelling and any signs of overheating
Earthing and bondingMain earthing conductor and protective bonding to the incoming gas and water pipes
Circuits and cablesInsulation resistance, continuity, visible cable condition and protection of cables buried in walls
Sockets, switches and fittingsDamage, scorching, loose fixings, polarity and suitability for the room
Bathrooms and kitchensEquipment near baths and showers, extractor fans, electric showers, cooker and hob circuits
Fixed appliancesHard-wired items such as immersion heaters, storage heaters and fused spurs

We inspect against the current IET Wiring Regulations. BS 7671:2018+A4:2026 was published on 15 April 2026, and the previous version is withdrawn in mid-October 2026. An older installation does not fail simply because the rules have moved on: the inspector codes what is actually dangerous or in need of improvement.

How often do landlords need an EICR?

Private landlords in England must have the installation inspected and tested at least every 5 years, or sooner if the last report recommends a shorter interval. The duty comes from the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 (SI 2020/312), which applied to new tenancies from 1 July 2020 and to all existing tenancies from 1 April 2021.

Property typeRecommended maximum interval
Privately rented home5 years or change of occupancy (legal maximum: 5 years)
HMO5 years, plus any borough licence conditions
Owner-occupied home10 years
Shops, offices and other commercial premises5 years

These intervals come from IET Guidance Note 3. Booking a fresh inspection between tenancies is a sensible habit: you can hand the incoming tenant a current report on day one and fix any problems while the property is empty. Business premises follow a different framework, explained on our commercial EICR page.

What must a landlord do once the report is issued?

You must share the report, keep it, and fix any defects within fixed deadlines. Under SI 2020/312 a landlord must:

  • give a copy to existing tenants within 28 days of the inspection;
  • give a copy to a new tenant before they move in;
  • give a copy to a prospective tenant within 28 days of their request;
  • send a copy to the local authority within 7 days of a request;
  • keep a copy for the electrician carrying out the next inspection;
  • complete any remedial work or further investigation within 28 days, or sooner if the report says so, then give written confirmation to tenants and the local authority within 28 days of completion.

Councils can impose financial penalties of up to £30,000 per breach. The wording is set out in the 2020 regulations and in the government’s guidance for landlords, tenants and local authorities.

Your EICR will also be needed for the Private Rented Sector Database created by the Renters’ Rights Act 2025. Every landlord must register each rented property and provide its EICR, gas safety record and EPC. Registration opens for London on 15 July 2027, the London deadline is 14 October 2027, and the annual fee is £65 per property. HMO landlords should also read their borough’s licence conditions, which commonly require a satisfactory EICR.

What do the codes C1, C2, C3 and FI mean?

Each observation is coded by severity. Any C1, C2 or FI makes the overall report unsatisfactory, while C3 observations on their own do not.

CodeMeaningExample from a London inspection
C1Danger present, immediate action requiredExposed live conductors behind a cracked socket or switch plate
C2Potentially dangerous, urgent remedial action requiredNo main protective bonding to the gas or water pipes, or a scorched accessory
C3Improvement recommendedMissing circuit chart, or no warning notice where old and new cable colours meet
FIFurther investigation required without delayA circuit that cannot be traced, or unexpectedly low insulation readings

Where possible, our electrician makes a C1 safe before leaving, usually by isolating the circuit, and explains the repair needed. Our guide to EICR codes explained shows how inspectors decide between codes.

What problems do we find in London properties?

Each type of London home tends to produce its own pattern of observations. These are the ones our electricians come across most.

  • Victorian and Edwardian conversions. Houses split into flats often have meters and consumer units in a shared hallway or under the stairs, circuits extended during loft and kitchen projects, and occasionally a light or socket in one flat fed from another. We trace these carefully, because a circuit nobody can isolate is a circuit nobody can work on safely.
  • Mansion blocks and older purpose-built flats. Older consumer units with limited RCD protection are common, as is bonding that was never upgraded when the plumbing changed. The supply cables in the common parts belong to the freeholder, so the report records clearly where the flat’s installation begins.
  • HMOs. Several consumer units, a separate landlord’s supply for hallway lighting and the fire alarm, and bedrooms running on adaptors and extension leads. Every board is tested, and we note where extra sockets would cut the reliance on trailing leads.
  • New-build flats. Modern installations usually test well, but we still find consumer units boxed into cupboards with poor access, missing labels, and integrated kitchen appliances with no accessible way to isolate them.

What happens if your EICR is unsatisfactory?

You have 28 days, or less if the report specifies, to complete the remedial work or further investigation. You do not normally need a brand new EICR afterwards: the original report plus written confirmation of the completed work is the evidence the regulations ask for.

Every unsatisfactory report we issue comes with an itemised list of coded observations and a fixed price to put them right. Typical remedials are replacing damaged accessories, installing main protective bonding, adding RCD protection or, where the board itself is the problem, a consumer unit replacement. When the work is finished you receive a Minor Electrical Installation Works Certificate or an Electrical Installation Certificate, depending on the job, ready to send to your tenants and the council.

You can use any competent electrician for the remedials. What matters is that the work is completed within the deadline and that you can prove it.

How should you prepare for the inspection?

Good preparation keeps the visit short and avoids ‘limitations’ on the report, which is where the electrician records parts of the installation they could not reach.

  • Give tenants written notice in good time and warn them the power will be off in stages.
  • Clear access to the consumer unit, meter cupboard, loft hatch and any cupboards hiding fused spurs or immersion heaters.
  • For flats, arrange keys or codes for communal meter cupboards and tell us about parking or visitor permits.
  • Ask tenants to shut down computers and keep fridge and freezer doors closed while circuits are off.
  • Have the previous EICR ready. It shows earlier limitations and recommendations, and you are required to keep it for the next inspector anyway.

Domestic EICRs start at £79 inc. VAT for a studio with one consumer unit. If you also need a gas safety record, our landlord gas and electrical bundle starts from £154. Our engineers have been certifying London properties since 2018, across all 32 boroughs and the City of London.

EICR prices in London (inc. VAT)

EICR prices in London (inc. VAT)
OptionPrice (inc. VAT)Notes
Studio flat£79One consumer unit
1–2 bedroom property£99One consumer unit
3–4 bedroom property£119One consumer unit
5–6 bedroom property£149One consumer unit
Each additional consumer unit£65–£85Common in HMOs and larger houses

All prices include VAT and cover one consumer unit; each additional consumer unit is £65–£85. Central London parking or Congestion Charge may be added; we always confirm before booking.

Book this service

What's included

  • Visual inspection and testing of the fixed installation to BS 7671
  • Testing of every circuit and RCD on one consumer unit
  • Digital EICR emailed, usually within 24–48 hours
  • Coded observations with plain-English explanations
  • C1 dangers made safe on the day where possible
  • Fixed-price quote for any remedial work
  • Report ready to share with tenants, agents and the council

How it works

  1. Book and confirm

    Tell us the property size and number of consumer units. We confirm the fixed price, any parking charges and an arrival window.

  2. Inspection and testing

    A NICEIC / NAPIT registered electrician inspects and tests every circuit to BS 7671, isolating the power in stages.

  3. Report issued

    Your EICR is emailed, usually within 24–48 hours, with every observation coded and an overall satisfactory or unsatisfactory result.

  4. Remedials if needed

    If anything is coded C1, C2 or FI, we quote to fix it and issue written confirmation once the work is complete.

EICR Certificate: frequently asked questions

How much does an EICR cost in London?

A domestic EICR with BritCertify costs £79 inc. VAT for a studio, £99 for 1–2 bedrooms, £119 for 3–4 bedrooms and £149 for 5–6 bedrooms. Each price covers one consumer unit, and each additional consumer unit is £65–£85. Central London parking or Congestion Charge may be added, and we always confirm the full price before booking.

How long is an EICR valid for a rented property?

Up to 5 years for a privately rented home in England, unless the electrician recommends a shorter interval on the report, in which case the earlier date applies. An unsatisfactory report is not a clean bill of health: the landlord must complete the remedial work within 28 days and keep written confirmation alongside the report.

Is an EICR the same as a landlord electrical safety certificate?

In everyday use, yes. Agents and tenants often ask for an 'electrical safety certificate', but the document the 2020 regulations require is an Electrical Installation Condition Report. It is a report rather than a pass certificate: it records the condition of the installation, codes any defects and gives an overall result of satisfactory or unsatisfactory.

How long does an EICR take?

Most one and two bedroom flats are inspected within a morning or an afternoon. Larger houses, HMOs and properties with more than one consumer unit take longer, as do installations where circuits are hard to trace. The power is switched off in stages during testing, so tenants should plan around short interruptions. We confirm an arrival window when you book.

Do I need an EICR to sell my home?

No law requires an EICR when selling an owner-occupied home in England, and the recommended interval for owner-occupiers is 10 years. Some sellers commission one anyway, because buyers often ask about the condition of the electrics and a recent report answers the question with evidence. If the property is let, the landlord duties continue until the sale completes.

What if my EICR only has C3 observations?

A report with only C3 observations is satisfactory, because C3 means improvement is recommended rather than that something is unsafe. There is no legal deadline to act on a C3. It is still worth budgeting for the work before the next inspection, especially if you plan to alter or extend the installation, when the issue may need resolving anyway.

Written and checked by the BritCertify technical team. Last reviewed 6 October 2026.

Book your EICR Certificate today

Tell us the property type and postcode and we will confirm a fixed price, including VAT, and the earliest available slot.